{"product_id":"crestron-chv-thstat-pir-10-w-t","title":"CTN CHV-THSTAT-PIR-10-W-T Heating\/Cooling Thermostat, 0-10V or Relay Control, with Occupancy Sensor, White Textured","description":"\u003cdiv class=\"crestron-product-description\"\u003e\n\u003cp\u003eThe CHV-THSTAT-PIR-10 thermostat enables precision control of two stage heat\/cool systems, two stage heat pump systems with an auxiliary heat stage, 2-pipe and 4-pipe FCU systems, and humidity systems.\u003c\/p\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv aria-labelledby=\"panel1-label\" class=\"tabs-panel is-active\" id=\"panel1\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"small-14 medium-9 medium-offset-1 column\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe CHV-THSTAT-PIR-10 thermostat enables precision control of two stage heat\/cool systems, two stage heat pump systems with an auxiliary heat stage, 2‑pipe and 4‑pipe FCU systems, and humidity systems. Achieve variable heating, cooling, and fan speed control in hotels, apartments, or other multi-dwelling residences with 0-10V or relay control options. A built-in passive infrared (PIR) sensor detects room occupancy for energy efficiency. Whether used as a standalone unit or as part of a complete Crestron control system, the CHV-TSTAT-PIR-10 delivers complete functionality in a stylish wall mount design.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eSimple Operation\u003c\/strong\u003e\u003cbr\u003e\nThe backlit LCD display with a simple user interface and intuitive push buttons make this thermostat easy to use and ideal for hospitality installs. The screen displays useful information such as the current setpoint, mode, fan setting, and (optionally) the current room temperature. The thermostat provides buttons for raising or lowering the temperature, changing the climate mode, adjusting the fan speed, and toggling between Fahrenheit and Celsius.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eComplete Climate Control\u003c\/strong\u003e\u003cbr\u003e\nClimate control features include separate heating and cooling setpoints, with an optional automatic changeover between heating and cooling modes. Adjustable anticipators and staging parameters ensure a comfortable space. Continuous fan operation can be selected when needed for increased circulation.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eOccupancy Sensing\u003c\/strong\u003e\u003cbr\u003e\nBuilt with versatility and energy efficiency in mind, the CHV‑THSTAT‑PIR‑10 features a built-in PIR sensor to ensure that energy spent on climate control is never wasted on a vacant room.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eAutomation System Integration\u003c\/strong\u003e\u003cbr\u003e\nMultiple Crestron thermostats may be networked via Cresnet wired communications, a simple 4-wire network bus that acts as the communications backbone for Crestron lighting dimmers, keypads, shades, thermostats, and other devices. Integrate the thermostat network with a Crestron control system to enable global temperature and humidity adjustments from any thermostat in the system.\u003c\/p\u003e\n\n                            \n                                    \u003c\/div\u003e\n\n\n                                     \n                                \u003c\/div\u003e\n\u003cdiv class=\"small-14 medium-4 column medium-offset-1 column end\"\u003e\n\u003cdiv class=\"in-the-box\"\u003e\n\u003cdiv\u003e\n\u003cimg alt=\"TAA Compliant\" class=\"badge\" src=\"https:\/\/kenticoprod.azureedge.net\/kenticoblob\/crestron\/media\/crestron\/generalsiteimages\/badges\/badge_taa_dark.png?ext=.png\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv class=\"overview_features\"\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with conventional heat\/cool 2H\/2C systems, heat pump 2H\/2C systems with auxiliary heat, dual-fuel heat pump, 2‑Pipe FCU, 4‑Pipe FCU, and humidity control\u003c\/li\u003e\n\u003cli\u003eSupports 0-10V or relay control for heating, cooling, and fan speed\u003c\/li\u003e\n\u003cli\u003eBacklit LCD display\u003c\/li\u003e\n\u003cli\u003eLarge, backlit push buttons for heating, cooling, fan speed, temperature scale, and temperature adjustments\u003c\/li\u003e\n\u003cli\u003eBuilt-in passive infrared (PIR) sensor to detect room occupancy for energy efficiency\u003c\/li\u003e\n\u003cli\u003eDesignate up to four setpoints based on occupancy and hospitality room booking status\u003c\/li\u003e\n\u003cli\u003eExternal temperature\/humidity sensor input enables the use of an extra, alternative, or auto-changeover sensor\u003c\/li\u003e\n\u003cli\u003eControl system integration via the Cresnet® network\u003c\/li\u003e\n\u003cli\u003eUtilizes built-in temperature and humidity sensors\u003c\/li\u003e\n\u003cli\u003eWall-mount installation\u003c\/li\u003e\n\u003cli\u003eAvailable in white and black finishes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eMeasurement Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e0º to 110ºF (-18-43ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eTemperature and Humidity Tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"30%\"\u003eOver Full Range\u003c\/td\u003e\n\u003ctd\u003e±1ºF (±0.5ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eSetpoint Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat\u003c\/td\u003e\n\u003ctd\u003e38° to 89°F (3° to 32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCool\u003c\/td\u003e\n\u003ctd\u003e59° to 99°F (15° to 37°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eRelay Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e1A @ 40VDC or 24VAC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003ePower Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCresnet® Network\u003c\/td\u003e\n\u003ctd\u003e24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVAC Unit\u003c\/td\u003e\n\u003ctd\u003e24VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: The device can be powered entirely via Cresnet 24VDC by placing a jumper between the Cresnet 24\/G and HVAC 24R\/24C connections and setting the POWER jumper to 24R. Powering the CHV‑THSTAT‑PIR‑10 from the HVAC system is recommended when possible.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eCommunications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCresnet Wired\u003c\/td\u003e\n\u003ctd\u003eControl system integration or networking;\u003cbr\u003e\n\t\t\tUnit is a fully functional standalone thermostat and does not require a connection to the Cresnet network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eButtons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eSwitches between Off, Heat, Cool, and Auto modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFAN\u003c\/td\u003e\n\u003ctd\u003eControls fan speed;\u003cbr\u003e\n\t\t\tCycles through Auto, High, Medium, and Low settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUP\u003c\/td\u003e\n\u003ctd\u003eRaises the room's setpoint by 1.0ºF, 1.0ºC, or 0.5ºC, depending on the active temperature scale and device settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDown\u003c\/td\u003e\n\u003ctd\u003eLowers the room’s setpoint by 1.0ºF, 1.0ºC, or 0.5ºC, depending on the active temperature scale and device settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC|F\u003c\/td\u003e\n\u003ctd\u003eSwitches between Fahrenheit and Celsius temperature scales\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eMotion Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOn-board passive infrared sensor;\u003cbr\u003e\n\t\t\tEnables thermostat to switch between four previously defined setpoints based on occupancy and hospitality room booking status;\u003cbr\u003e\n\t\t\tWhen motion is detected, the Occupied setpoint is used;\u003cbr\u003e\n\t\t\tWhen the room is vacant, the Unoccupied setpoint is used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Range\u003c\/td\u003e\n\u003ctd\u003e15 ft (4.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Angle\u003c\/td\u003e\n\u003ctd\u003e144 degrees horizontal;\u003cbr\u003e\n\t\t\t30 degrees vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDisplays current room temperature, current setpoint, current Heat or Cool mode, thermostat’s call for heating or cooling, and current fan setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTransflective LCD, backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e2.75 in. (70 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e128 x 64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewing Angle\u003c\/td\u003e\n\u003ctd\u003e±50° horizontal at 0° vertical;\u003cbr\u003e\n\t\t\t±50° vertical at 0° horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eConnections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24C\u003c\/td\u003e\n\u003ctd\u003e(3) Common for 24VAC\/VDC device power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24R\u003c\/td\u003e\n\u003ctd\u003e(1) 24VAC\/VDC Device Power Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003e(1) Reference voltage for heat, cool, compressor and fan relay calls.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGH\u003c\/td\u003e\n\u003ctd\u003eNon-FCU: (1) Fan call\u003cbr\u003e\n\t\t\tFCU: (1) Fan call (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGM*\u003c\/td\u003e\n\u003ctd\u003eNon-FCU: (1) W2 or O call;\u003cbr\u003e\n\t\t\tFCU: (1) Fan call (medium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGL*\u003c\/td\u003e\n\u003ctd\u003eNon-FCU: (1) Y2 (compressor stage 2) call;\u003cbr\u003e\n\t\t\tFCU: (1) Fan call (low)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eNon-FCU: (1) Cool or compressor stage 1 call;\u003cbr\u003e\n\t\t\tFCU (4-Pipe): (1) Cool valve call;\u003cbr\u003e\n\t\t\tFCU (2-Pipe C): (1) Cool valve call\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW\u003c\/td\u003e\n\u003ctd\u003eNon-FCU: (1) Heat call;\u003cbr\u003e\n\t\t\tFCU (4-Pipe): (1) Heat valve call;\u003cbr\u003e\n\t\t\tFCU (2-Pipe H\/C): (1) Valve call;\u003cbr\u003e\n\t\t\tFCU (2-Pipe H): (1) Heat valve call\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHUM\u003c\/td\u003e\n\u003ctd\u003e(1) Humidistat call\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRHU\u003c\/td\u003e\n\u003ctd\u003e(1) Reference, humidistat call\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS+ and TS-\u003c\/td\u003e\n\u003ctd\u003e(2) Remote sensor inputs, comprised of TS1+ and TS1- terminals;\u003cbr\u003e\n\t\t\tFor remote temperature sensors (\u003ca alt=\"http:\/\/crestron.com\/model\/6500380\" href=\"http:\/\/crestron.com\/model\/6500380\" target=\"_blank\" title=\"http:\/\/crestron.com\/model\/6500380\"\u003eCHV‑RTS\u003c\/a\u003e, \u003ca alt=\"http:\/\/crestron.com\/model\/6508139\" href=\"http:\/\/crestron.com\/model\/6508139\" target=\"_blank\" title=\"http:\/\/crestron.com\/model\/6508139\"\u003eCHVI‑RTS‑1G‑N‑W\u003c\/a\u003e, and \u003ca alt=\"http:\/\/crestron.com\/model\/6508140\" href=\"http:\/\/crestron.com\/model\/6508140\" target=\"_blank\" title=\"http:\/\/crestron.com\/model\/6508140\"\u003eCHVI‑RTS‑1G‑SM‑W\u003c\/a\u003e), remote slab sensor (\u003ca alt=\"http:\/\/crestron.com\/model\/6500593\" href=\"http:\/\/crestron.com\/model\/6500593\" target=\"_blank\" title=\"http:\/\/crestron.com\/model\/6500593\"\u003eCHV‑RSS\u003c\/a\u003e), remote temperature and humidity sensors (\u003ca alt=\"http:\/\/crestron.com\/model\/6500455\" href=\"http:\/\/crestron.com\/model\/6500455\" target=\"_blank\" title=\"http:\/\/crestron.com\/model\/6500455\"\u003eCHV‑RTHS\u003c\/a\u003e), and 10k thermistors (all sensors and thermistors are sold separately);\u003cbr\u003e\n\t\t\tUsing CAT5 or similar low-capacitance wire, connect up to (2) Crestron temperature sensors, (1) Crestron temperature\/humidity sensor, or (1) 10k thermistor;\u003cbr\u003e\n\t\t\tCan also be designated as an autochangeover sensor for an FCU 2-pipe heat\/cool system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"notebox\" colspan=\"2\"\u003e\n\u003cem\u003eNotes:\u003c\/em\u003e\n\u003cul class=\"padding-top: 10px;\"\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eTS1+\u003c\/strong\u003e and \u003cstrong\u003eTS1-\u003c\/strong\u003e connections are non-polarized. The + and - designations are provided to simplify wiring.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eUse a seperate run of wire for each sensor.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eSensor lines should not be run parallel to any other wiring. Lines should cross other cables at right angles.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eUsing one twisted pair on CAT5\/CAT6 or similar low-capacitance wire allows wiring lengths up to 500ft (152 m) from the CHV-THSTAT-PIR-10.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eIf possible, use STP cable and connect the shield to ground. If no ground is present, connect the shield to the thermostat 24C connection.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eIn situations where ordinary two-conductor thermostat wire (18 or 20 AWG) has been installed, it may be used for runs up to 100ft (30m) but this is not a preferred method of installation.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGM\u003c\/td\u003e\n\u003ctd\u003e(1) 0-10V fan control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWM\u003c\/td\u003e\n\u003ctd\u003eFCU (4-Pipe): (1) Heat valve call\u003cbr\u003e\n\t\t\tFCU (2-Pipe H\/C): (1) Valve call\u003cbr\u003e\n\t\t\tFCU (2-Pipe H): (1) Heat valve call\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYM\u003c\/td\u003e\n\u003ctd\u003eFCU (4-Pipe): (1) Cool valve call\u003cbr\u003e\n\t\t\tFCU (2-Pipe C): (1) Cool valve call\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCresnet Network\u003cbr\u003e\n\t\t\t(G, Z, Y, 24)\u003c\/td\u003e\n\u003ctd\u003e(1) 4-position terminal block;\u003cbr\u003e\n\t\t\tCresnet device port, connects to Cresnet control network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95% RH (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e32° to 122°F (0° to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eConstruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWhite or black plastic, surface-mountable to the front of a horizontally-oriented 1-gang electrical box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e4.00 in. (102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e5.00 in. (127 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e1.10 in. (28 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e5.80 oz (165 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eCompliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cstrong\u003eRegulatory Model: M202349001\u003c\/strong\u003e\u003cbr\u003e\n\t\t\tETL Listed for the United States and Canada to UL\/IEC 60730-2-9 safety standards. CE compliant for applicable European market requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Crestron","offers":[{"title":"Default Title","offer_id":67572108525858,"sku":"CHV-THSTAT-PIR-10-W-T","price":381.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/2228\/6114\/files\/master_photo_a-CHV-THSTAT-PIR-10-W-T_FrontRight15.png?v=1792614599","url":"https:\/\/deputyelectronics.com\/products\/crestron-chv-thstat-pir-10-w-t","provider":"Deputy Electronics","version":"1.0","type":"link"}