{"product_id":"crestron-clb-120-20a-afci","title":"CTN CLB-120-20A-AFCI Combination Arc Fault Breaker for CAEN-MLO, 120V, 20A","description":"\u003cdiv class=\"crestron-product-description\"\u003e\n\u003cp\u003eChoice of thermal magnetic, combination arc fault, and ground fault type circuit breakers for CAEN-MLO automation enclosures.\u003c\/p\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv aria-labelledby=\"panel1-label\" class=\"tabs-panel is-active\" id=\"panel1\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"small-14 medium-9 medium-offset-1 column\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eTo ensure premium electrical circuit protection for our \u003ca class=\"linknormal\" href=\"\/resources\/product_and_programming_resources\/catalogs_and_brochures\/online_catalog\/default.asp?jump=1\u0026amp;model=CAEN-MLO\" target=\"_blank\"\u003eCAEN-MLO\u003c\/a\u003e automation enclosures, Crestron® has selected Eaton® Type CH circuit breakers. These breakers are available directly from Crestron in a choice of thermal magnetic, ground fault, and combination arc fault breaker types.\u003c\/p\u003e\n\u003cp\u003eEaton CH circuit breakers feature a quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. These breakers trip to the OFF position, clearly identifying which breaker has tripped and allowing for simple one-step reset. Each breaker also includes a trip flag to differentiate between a trip and the breaker being turned off.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePlug-on Neutral\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCombination arc fault and ground fault models feature an innovative plug-on neutral design that eliminates the need for individual pigtails wired to a separate bus bar. This feature saves time during installation, eliminates nuisance tripping due to loose pigtail connections, and allows for a cleaner, more serviceable assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCombination Arc Fault Breakers\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eArcing faults are a common cause of many home electrical fires, which can occur when insulation around cords, wires, or cables is damaged or deteriorated. A combination type arc fault circuit interrupter (AFCI) offers mitigation of high current arcing faults in the complete circuit, including connected cords. In addition, it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Beginning in 2008, the National Electrical Code® requires all circuits feeding dwelling areas in residential structures to be protected by combination type arc fault circuit interrupters.\u003c\/p\u003e\n\u003cp\u003eEaton combination arc fault breakers are rigorously tested and proven to work reliably with Crestron dimmers, exhibiting excellent immunity to nuisance tripping under dimmed loads up to 2000 Watts. Built-in diagnostics ensure reliable protection, with visual trip indication provided via a diagnostic LED. Diagnostic trip codes are displayed by the LED using blinking patterns as follows:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e\u003cb\u003eBlink Pattern\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eDescription\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eMechanical Disconnect - \u003c\/b\u003eThe breaker has detected an overload, short circuit, or was manually turned off.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eLow Current Arc - \u003c\/b\u003eA low current \"series\" arc has been detected within one of the current pathways. These arcs are typically found in worn or degraded appliance and extension cords, poor connections in appliances or fixtures, or in contacts within equipment.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eHigh current Arc - \u003c\/b\u003eA high current \"parallel\" arc has been detected between two conductors. These arcs are usually found in installed wiring where the wire has been compromised by a nail or screw, an over tightened staple, or damaged insulation.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eShort Delay - \u003c\/b\u003eShort delay is an electronic backup to the short circuit mechanism.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eOvervoltage - \u003c\/b\u003eA voltage of 160V RMS or greater has been detected. After resetting the breaker, press the \"TEST\" button to verify the breaker is working properly.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eGround Fault - \u003c\/b\u003eThe breaker has detected that current has found an alternate path to ground.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"101\"\u003e\n\u003cp align=\"center\"\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"580\"\u003e\n\u003cp align=\"left\"\u003e\u003cb\u003eSelf Test Failure - \u003c\/b\u003eThe breaker continually tests its internal electronics and software to ensure the arc fault detection technology is working properly. The breaker will trip in the event of a self test failure.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eGround Fault Breakers\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA ground fault current interrupter (GFCI) provides superior safety for electrical outlets in areas where electricity may come into contact with water. A GFCI immediately breaks the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. A GFCI is required in any application where outlets are located near water such as kitchen countertops, bathrooms, swimming pools, hot tubs, and outdoor receptacles.\u003c\/p\u003e\n\n                            \n                                    \u003c\/div\u003e\n\n\n                                     \n                                \u003c\/div\u003e\n\u003cdiv class=\"small-14 medium-4 column medium-offset-1 column end\"\u003e\n\u003cdiv class=\"in-the-box\"\u003e\n\u003cdiv\u003e\n\u003cimg alt=\"TAA Compliant\" class=\"badge\" src=\"https:\/\/kenticoprod.azureedge.net\/kenticoblob\/crestron\/media\/crestron\/generalsiteimages\/badges\/badge_taa_dark.png?ext=.png\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv class=\"overview_features\"\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEaton® Type CH circuit breakers\u003c\/li\u003e\n\u003cli\u003eChoice of thermal magnetic, combination arc fault, and ground fault types\u003c\/li\u003e\n\u003cli\u003eQuick-make, quick-break switch mechanism\u003c\/li\u003e\n\u003cli\u003eInverse time element tripping operation\u003c\/li\u003e\n\u003cli\u003eTwo position, trip to \"OFF\" handle with trip flag\u003c\/li\u003e\n\u003cli\u003ePlug-on neutral (AFCI and GFCI models)\u003c\/li\u003e\n\u003cli\u003eAvoids nuisance tripping under dimmed loads up to 2000 Watts (AFCI model)\u003c\/li\u003e\n\u003cli\u003eBuilt-in diagnostics with LED indicator (AFCI model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"6\"\u003eAvailable Models \u0026amp; Ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eType\u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eAmpere Rating\u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eEaton Model #\u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eCrestron Model #\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eThermal Magnetic,\u003cbr\u003e\n\t\t\tSingle-Pole, 10 kAIC\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e20 A\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e120 VAC\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eCHF120\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eCLB-120-20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eCombination Arc Fault Interrupter,\u003cbr\u003e\n\t\t\tSingle-Pole, 10 kAIC\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e20 A\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e120 VAC\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eCHFCAF120PN\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eCLB-120-20A-AFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eGround Fault Interrupter,\u003cbr\u003e\n\t\t\tSingle-Pole, 10 kAIC\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e20 A\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e120 VAC\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eCHFGF120PN\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eCLB-120-20A-GFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Crestron","offers":[{"title":"Default Title","offer_id":67572109738274,"sku":"CLB-120-20A-AFCI","price":156.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/2228\/6114\/files\/master_photo_a-clb-120_f4709fe4-58a0-4cea-8b0f-63e10fe35680.png?v=1792614635","url":"https:\/\/deputyelectronics.com\/products\/crestron-clb-120-20a-afci","provider":"Deputy Electronics","version":"1.0","type":"link"}