{"product_id":"crestron-csa-pws10s-hub-enet","title":"CTN CSA-PWS10S-HUB-ENET 10-Motor Power Supply with Ethernet to Cresnet® Bridge and Cresnet Hub","description":"\u003cdiv class=\"crestron-product-description\"\u003e\n\u003cp\u003ePowers up to 10 Crestron® Quiet Motor Technology™ roller shade or drapery system motors and features an Ethernet to Cresnet® bridge and a built-in, 5-segment Cresnet hub.\u003c\/p\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv aria-labelledby=\"panel1-label\" class=\"tabs-panel is-active\" id=\"panel1\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"small-14 medium-9 medium-offset-1 column\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe CSA-PWS10S-HUB-ENET Power Supply powers up to 10 Crestron® Quiet Motor Technology™ roller shade or drapery system motors through a home run to each motor, and features an Ethernet to Cresnet® bridge and a built-in, 5-segment Cresnet® hub.  The embedded Ethernet to Cresnet bridge provides the flexibility necessary for a multitude of installation configurations with the added benefit of high-speed communications.  Any hub set to Ethernet becomes a Cresnet hub master for any daisy-chained hubs that are set to Cresnet and connected to the hub.\u003csup\u003e[1,2]\u003c\/sup\u003e  A local control interface with LED feedback indicators allows roller shade or drapery systems to be tested without a control system connection.  In addition to network diagnostics capabilities, the CSA-PWS10S-HUB-ENET is convection cooled for silent operation and can be surface-mounted or mounted in a CAEN or CAEN-MLO enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Cresnet Bus\u003c\/strong\u003e\u2028\u003cbr\u003e\nCresnet is the communications backbone for many Crestron keypads, lighting controls, shade motors, thermostats, occupancy sensors, and other devices that don’t require the higher speed of Ethernet. It provides a dependable and flexible wiring solution, allowing multiple devices to be wired together in parallel using both home-run and daisy-chain topologies.\u003csup\u003e[2]\u003c\/sup\u003e  The Cresnet bus distributes bidirectional data communication and 24VDC power to each device over a single 4-conductor cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet to Cresnet Bridge\u003c\/strong\u003e\u003cbr\u003e\nAdding one or more CSA-PWS10S-HUB-ENETs to a Crestron Shading Solutions System enables the distribution of Cresnet over high-speed Ethernet.\u003csup\u003e[1]  \u003c\/sup\u003eThe increased bandwidth afforded by Ethernet reduces latency for overall improved speed and performance.  By leveraging existing LAN infrastructure in any facility, wiring distances can be extended easily while potentially reducing the overall wiring requirements.  Multiple hubs can communicate solely over Ethernet as long as they are each directly connected to an Ethernet source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Troubleshooting\u003c\/strong\u003e\u003cbr\u003e\nThe built-in diagnostics featured on the CSA-PWS10S-HUB-ENET enable the user to automatically shut down any branch with a fault, to identify the exact problem (e.g., Y shorted to Z, Z shorted to GND, overload, etc.) without a multimeter, and then to trigger program events based on problems detected by the power supply (e.g., display notices on touch screens and send emails to the service department).  For easy troubleshooting, the hub supports the ability to remotely cycle power to each shade or drapery motor that is connected to it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCAEN Enclosure Mounting\u003c\/strong\u003e\u003cbr\u003e\nThe CSA-PWS10S-HUB-ENET occupies a single module space in any \u003ca href=\"http:\/\/www.crestron.com\/products\/show_products.asp?jump=jump\u0026amp;model=CAEN\"\u003eCAEN\u003c\/a\u003e or \u003ca href=\"http:\/\/www.crestron.com\/resources\/product_and_programming_resources\/catalogs_and_brochures\/online_catalog\/default.asp?jump=1\u0026amp;model=CAEN-MLO\"\u003eCAEN-MLO\u003c\/a\u003e automation enclosure.  Ethernet to Cresnet Bridge and Cresnet Hub modules are controlled by the \u003ca href=\"http:\/\/www.crestron.com\/products\/show_products.asp?jump=jump\u0026amp;model=DIN-AP3\"\u003eDIN-AP3\u003c\/a\u003e and other 3-Series® control systems via the Cresnet network or via a control system with Ethernet communications.  \u003c\/p\u003e\n\n                            \n                                    \u003c\/div\u003e\n\n\n                                     \n                                \u003c\/div\u003e\n\u003cdiv class=\"small-14 medium-4 column medium-offset-1 column end\"\u003e\n\u003cdiv class=\"in-the-box\"\u003e\n\u003cdiv\u003e\n\u003cimg alt=\"CrestronHome\" class=\"badge\" src=\"https:\/\/kenticoprod.azureedge.net\/kenticoblob\/crestron\/media\/crestron\/generalsiteimages\/badges\/badge_crestronhome-os.jpg?ext=.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv class=\"overview_features\"\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for up to 10 Crestron® roller shade motors, 10 drapery system motors, or a combination of the two up to a total of 10\u003c\/li\u003e\n\u003cli\u003eBuilt-in 5-segment Cresnet® hub\u003c\/li\u003e\n\u003cli\u003eEthernet to Cresnet bridge\u003c\/li\u003e\n\u003cli\u003eAbility to remotely cycle power to each shade motor to assist in troubleshooting\u003c\/li\u003e\n\u003cli\u003eIndividual per-motor overcurrent protection\u003c\/li\u003e\n\u003cli\u003eLocal shade and drapery master controls\u003c\/li\u003e\n\u003cli\u003eClear diagnostic LED indicators\u003c\/li\u003e\n\u003cli\u003eConvection cooled for silent operation\u003c\/li\u003e\n\u003cli\u003eSurface-mountable or mountable in a CAEN enclosure \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eLoad Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eTotal Motors Supported\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eProvides power for up to (10) Crestron® roller shade motors, (10) drapery system motors, or a combination of the two up to a total of (10) motors with each motor homerun to the power supply;\u003cbr\u003e\n\t\t\t10 Drapery System solutions carry 145 lbs load each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eOutput\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e24 Volts DC, 60 Watt max\/output LPS\u003cbr\u003e\n\t\t\t250 Watts Total Continuous Load\u003cbr\u003e\n\t\t\t525 Watts 2 minutes ON, 10 minutes OFF Limited Duty Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eLoad Protection\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(10) Self-resetting thermal fuses, (1) per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003ePower Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eLine Power\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e110-240 Volts AC, 50\/60 Hz, 5.5 Amps max at 110 Volts AC, 2.7 Amps max at 240 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eConnections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eNET HOST IN, OUT\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(2) 4-pin 5 mm detachable terminal blocks;\u003cbr\u003e\n\t\t\tCresnet® slave ports, paralleled;\u003cbr\u003e\n\t\t\tConnect to Cresnet control network in Cresnet mode,\u003csup\u003e[1]\u003c\/sup\u003e power not supplied to these connections;\u003cbr\u003e\n\t\t\tCresnet power and data pass-through;\u003cbr\u003e\n\t\t\tUsed to daisy-chain to additional CSA-PWS10S-HUB-ENET modules when in Ethernet mode\u003csup\u003e[1,2]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eA-E, 1-10\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003e(10) 4-pin 5 mm detachable terminal blocks comprising (2) Cresnet ports per each of the (5) hub segments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eLAN\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003e(1) 8-pin RJ45, female;\u003cbr\u003e\n\t\t\t10Base-T\/100Base-TX Ethernet port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eUSB\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003e(1) USB Type B female, USB computer console port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eLine Power\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003e(1) Attached input power cable (~10 in long, 254 mm) with inline IEC 60320 C14 main power inlet;\u003cbr\u003e\n\t\t\tConnects to AC power source using grounded 3-prong IEC cord (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eMEMORY CARD\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003eNot used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eLED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003ePWR 1-10\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(10) Green LEDs, indicate 24 Volts present at each corresponding output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eNET A-E\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(5) Amber LEDs, indicate Cresnet or Ethernet activity on each corresponding hub segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eNET HOST\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(1) Amber LED, indicates Cresnet activity with control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eMSG\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(1) Red LED, indicates error messages and Test mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eButtons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eMODE\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(1) Switch, sets the unit to either Cresnet or Ethernet mode;\u003cbr\u003e\n\u003cstrong\u003eCRES:\u003c\/strong\u003e Enables Cresnet communications, unit functions as a slave device;\u003cbr\u003e\n\t\t\tAll daisy-chained hubs except for the master must be set to CRES\u003csup\u003e[1,2]\u003c\/sup\u003e\u003cbr\u003e\n\u003cstrong\u003eLAN:\u003c\/strong\u003e Enables Ethernet communications, unit functions as a master device;\u003cbr\u003e\n\t\t\tStandalone units set to LAN must be directly connected to a LAN source\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eMASTER UP\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(1) Pushbutton, press and hold to raise\/open all connected shades\/drapery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eMASTER DOWN\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(1) Pushbutton, press and hold to lower\/close all connected shades\/drapery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eTEST\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(1) Pushbutton, initiates or terminates diagnostic test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eRESET\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e(1) Recessed pushbutton, forces hardware reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eHousing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eMetal, grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eMounts in a CAEN or CAEN-MLO enclosure, 16-gauge galvanized steel enclosure with vented grey steel cover;\u003cbr\u003e\n\t\t\tSurface-mountable on a wall (indoor use only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eTemperature\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eHumidity\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003e10% to 90% RH (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003e55 BTU\/hr @ 120VAC input and 250W total output\u003cbr\u003e\n\t\t\t40 BTU\/hr @ 240VAC input and 250W total output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e7.71 in (196 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameEven\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueEven\"\u003e6.32 in (162 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e3.08 in (78 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"3\"\u003eWeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\" colspan=\"2\"\u003e3 lbs (1.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Crestron","offers":[{"title":"Default Title","offer_id":67572273348898,"sku":"CSA-PWS10S-HUB-ENET","price":1637.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/2228\/6114\/files\/master_photo_a-CSA-PWS10S-HUB-ENET.png?v=1792617449","url":"https:\/\/deputyelectronics.com\/products\/crestron-csa-pws10s-hub-enet","provider":"Deputy Electronics","version":"1.0","type":"link"}