{"product_id":"crestron-din-kxi-knx-secure-ip-gateway-din-rail-mount","title":"Crestron DIN KXI KNX Secure IP Gateway, DIN Rail Mount","description":"\u003cdiv class=\"crestron-product-description\"\u003e\n\u003cp\u003eSecure IP interface that connects to the KNX TP Bus.\u003c\/p\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv aria-labelledby=\"panel1-label\" class=\"tabs-panel is-active\" id=\"panel1\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"small-14 medium-9 medium-offset-1 column\"\u003e\n\u003cdiv\u003e\n                                        The DIN-KXI is an IP-based KNX interface that allows a 4-Series® \u003ca href=\"https:\/\/www.crestron.com\/Products\/Control-Hardware-Software\/Hardware\/Control-Systems\" target=\"_blank\"\u003econtrol system\u003c\/a\u003e to communicate with a KNX system. It is capable of addressing and controlling up to 1,000 datapoints and receives power over the KNX bus. The \u003cspan class=\"mc-variable TP-Variables.SortName variable\"\u003eDIN-KXI\u003c\/span\u003e can also be used as a programming interface for KNX devices using ETS5 or ETS6 software.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eKNX Security\u003c\/strong\u003e\u003cbr\u003e\nThe device supports KNX Security (AES-128) which can be enabled using ETS software.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eEthernet Communications\u003c\/strong\u003e\u003cbr\u003e\nThe Ethernet connection allows access to the KNX bus from any point on the LAN. This provides programming and diagnostics without direct access to the DIN-KXI.\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLocal Diagnostics\u003c\/strong\u003e\u003cbr\u003e\nThe buttons and LEDs on the device provide diagnostic data including the operating status and communication errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Installation\u003c\/strong\u003e\u003cbr\u003e\nThe 1M (18 mm) wide \u003cspan class=\"mc-variable TP-Variables.SortName variable\"\u003eDIN-KXI\u003c\/span\u003e snaps onto a standard DIN rail for installation in a wall mount enclosure. Wiring connections are made along the top and bottom, clearly accessible from the front for easy installation and servicing. All setup controls and indicators are positioned on the center front panel.\u003c\/p\u003e\n\n                            \n                                    \u003c\/div\u003e\n\n\n                                     \n                                \u003c\/div\u003e\n\u003cdiv class=\"small-14 medium-4 column medium-offset-1 column end\"\u003e\n\u003cdiv class=\"in-the-box\"\u003e\n\u003cdiv\u003e\n\u003cimg alt=\"TAA Compliant\" class=\"badge\" src=\"https:\/\/kenticoprod.azureedge.net\/kenticoblob\/crestron\/media\/crestron\/generalsiteimages\/badges\/badge_taa_dark.png?ext=.png\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv class=\"overview_features\"\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cul class=\"features\"\u003e\n\u003cli data-mc-conditions=\"Models.DIN-DLI,Models.DIN-KXI\"\u003e\n\u003cspan class=\"mc-variable Specifications.M-Width variable\"\u003e1\u003c\/span\u003eM wide DIN rail mounting\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003eEthernet to KNX interface\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003eIntegrates KNX with a Crestron® control system\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003eSupports KNXnet\/IP Security (AES-128)\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003eControls up to 1,000 KNX datapoints\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003eUp to 8 simultaneous KNXnet\/IP Tunneling connections\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003eConfigure using ETS Software\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003eOn-board controls for setup and diagnostics\u003c\/li\u003e\n\u003cli data-mc-conditions=\"Models.DIN-KXI\"\u003ePowered via the KNX bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" width=\"100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 25%;\"\u003e\n\u003ccol style=\"width: 75%;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eKNX Bus\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\u003cspan class=\"mc-variable Specifications.MainPower variable\"\u003e20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-2LEDPWM8,Models.DIN-8SW8-I,Models.DIN-1DIM4,Models.DIN-1DIMU4,Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eCommunications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eKNX\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eKNX over TP (Twisted Pair);\u003cbr\u003e\n\t\t\tInterface protocol: cEMI;\u003cbr\u003e\n\t\t\tMax. APDU length: 55;\u003cbr\u003e\n\t\t\tDevice model: System B;\u003cbr\u003e\n\t\t\tKNXnet\/IP Security (AES-128);\u003cbr\u003e\n\t\t\tCompatible with ETS5 and ETS6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eEthernet\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003eSupports ARP, ICMP, IGMP, UDP\/IP, TCP\/IP, DHCP, and Auto IP;\u003cbr\u003e\n\t\t\tDHCP is enabled by default, can be changed using the ETS Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"page-break-after: avoid;column-break-after: avoid;\"\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eConnectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eKNX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(2) 4-conductor KNX bus connectors, push-in style;\u003cbr\u003e\n\t\t\tConsisting of (1) Red (+) and (1) Black (-) connector, for power and communications;\u003cbr\u003e\n\t\t\tAccepts up to 4 solid-core twisted pairs;\u003cbr\u003e\n\t\t\t0.6 - 0.8 mm (22 - 20 AWG), strip wires 5 - 6 mm (0.2 - 0.24 in.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eLAN\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(1) 8-pin RJ-45, female;\u003cbr\u003e\n\t\t\t100BASE-TX Ethernet port;\u003cbr\u003e\n\t\t\tGreen and yellow LEDs indicate Ethernet port status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"\"\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eControls and Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eKNX PROG.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(1) Red LED and (1) recessed, miniature push button for entering Programming mode and factory reset;\u003cbr\u003e\n\t\t\tProgramming Mode: Press to enter Programming mode, the LED lights to indicate that Programming mode is activated;\u003cbr\u003e\n\t\t\tFactory reset: Press and hold while connecting the KNX bus, hold for 6 seconds until all LEDs flash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eKNX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(1) Multicolor LED, indicates power and KNX status;\u003cbr\u003e\n\t\t\tGreen: Indicates power is received from the KNX bus;\u003cbr\u003e\n\t\t\tFlashing Green Indicates communications on the KNX bus;\u003cbr\u003e\n\t\t\tFlashing Red: Indicates communications failure on the KNX bus\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eMODE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(1) Multicolor LED, indicates BAOS and IP tunnel status;\u003cbr\u003e\n\t\t\tGreen: Normal operating mode;\u003cbr\u003e\n\t\t\tRed: Programming mode is active;\u003cbr\u003e\n\t\t\tFlashes green (1 to 10 times): Manual mode is active, the selected BAOS connection (1 to 10) is not used and is available, the number of flashes indicates the connection number;\u003cbr\u003e\n\t\t\tFlashes Orange (1 - 10 times): Manual mode is active, the selected BAOS connection (1 - 10) is used;\u003cbr\u003e\n\t\t\tFlashes Green (1 - 5 times): Manual mode is active, the selected Tunnel (1 - 5) is not used and is available;\u003cbr\u003e\n\t\t\tFlashes Orange (1 - 5 times): Manual mode is active, the selected Tunnel (1 - 5) is used;\u003cbr\u003e\n\t\t\tFlashes Red: The configuration is not properly loaded\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eIP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(1) Multicolor LED, indicates Ethernet status;\u003cbr\u003e\n\t\t\tGreen: Active Ethernet link and valid IP settings;\u003cbr\u003e\n\t\t\tFlashes green: Ethernet activity;\u003cbr\u003e\n\t\t\tRed: Invalid IP settings or has not received IP settings from the DHCP server\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eCONN BAOS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(1) push button, to enter Manual mode and select a BAOS connection;\u003cbr\u003e\n\t\t\tPress to enter Manual mode and select a BAOS connection (1 - 10), the MODE LED indicates the selected BAOS connection number;\u003cbr\u003e\n\t\t\tTo exit Manual mode, press CONN BAOS and CONN TUNN simultaneously\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"Models.DIN-KXI\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eCONN TUNN\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e(1) push button, to enter Manual mode and select a tunnel connection;\u003cbr\u003e\n\t\t\tPress to enter Manual mode and select a TUNN connection (1 - 5), the MODE LED indicates the selected tunnel connection number;\u003cbr\u003e\n\t\t\tTo exit Manual mode, press CONN BAOS and CONN TUNN simultaneously\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eTemperature\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\u003cspan class=\"mc-variable Specifications.Temperture variable\"\u003e-5° to 45°C (23° to 113°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eHumidity\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\u003cspan class=\"mc-variable Specifications.Humidity variable\"\u003e5% to 93% RH (noncondensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"page-break-after: avoid;column-break-after: avoid;\"\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eConstruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eEnclosure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp data-mc-conditions=\"Models.DIN-2LEDPWM8,Models.DIN-8SW8-I,Models.DIN-KXI\"\u003eLight gray polycarbonate housing with polycarbonate label overlay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"\"\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003e\n\u003cp\u003eMounting\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cp\u003e35 mm DIN EN 60715 rail mount, DIN 43880 form factor for enclosures with 45 mm front panel cutout, occupies \u003cspan class=\"mc-variable Specifications.DINSpaces variable\"\u003e1 DIN module space (18 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\u003cspan class=\"mc-variable Specifications.Height variable\"\u003e90 mm (3.55 in.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\n\u003cspan class=\"mc-variable Specifications.Width variable\"\u003e18 mm (0.71 in)\u003c\/span\u003e \u003cmadcap:conditionaltext data-mc-conditions=\"Models.DIN-KXI\"\u003e;\u003cbr\u003e\n\t\t\t1M wide\u003c\/madcap:conditionaltext\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDNameOdd\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"productSpecTDValueOdd\"\u003e\u003cspan class=\"mc-variable Specifications.Depth variable\"\u003e62 mm (2.44 in.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"\"\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mc-conditions=\"\"\u003e\n\u003ctd class=\"productSpecTDValueOdd\" colspan=\"2\"\u003e\u003cspan class=\"mc-variable Specifications.Weight variable\"\u003e40 g (1.41 oz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eCompliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDValueOdd\" colspan=\"2\"\u003e\n\u003cp colspan=\"2\" data-mc-conditions=\"Models.DIN-1DIM4,Models.DIN-2LEDPWM8,Models.DIN-8SW8-I,Models.DIN-KXI\"\u003e\u003cstrong\u003eRegulatory Model: \u003cspan class=\"mc-variable TP-Variables.RegulatoryModel variable\"\u003eM202234003\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cspan class=\"mc-variable Specifications.Compliance variable\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Crestron","offers":[{"title":"Default Title","offer_id":67572304511266,"sku":"CTN-DIN-KXI","price":393.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/2228\/6114\/files\/master_photo_a-DIN-KXI.png?v=1792617726","url":"https:\/\/deputyelectronics.com\/products\/crestron-din-kxi-knx-secure-ip-gateway-din-rail-mount","provider":"Deputy Electronics","version":"1.0","type":"link"}