{"product_id":"crestron-pc-350v-18","title":"CTN PC-350V-18 18-Outlet Vertical Networked Power Controller \u0026 Conditioner with Surge Protection and Metering","description":"\u003cdiv class=\"crestron-product-description\"\u003e\n\u003cp\u003eA vertical rack-mountable 12A, 120V AC power controller, conditioner, and surge protector for professionally installed AV and IT systems. The PC-350V-18 is designed to be mounted on the rack frame, hence occupies no rack space (Zero RU).\u003c\/p\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv aria-labelledby=\"panel1-label\" class=\"tabs-panel is-active\" id=\"panel1\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"small-14 medium-9 medium-offset-1 column\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe PC-350V-18 is a vertical rack-mountable power controller designed to occupy no rack space (zero RU). It provides 120V AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. All 18 individually-switched outlets are protected and monitored, including 12 outlets with EMI and RFI noise filtering. Ping monitoring and power cycle scheduling are adjustable to ensure connected devices are always operational. Power cycle delays and sequencing are adjustable to ensure a system powers up reliably every time. The switched outlets are also individually controllable via a control system to enable independent switching of devices, load-shedding, and other custom power control functionality.\u003csup\u003e1\u003c\/sup\u003e\u003cbr\u003e\n\u003cbr\u003e\nLine voltage, current, power, and energy usage monitoring at each outlet is possible for troubleshooting and to prevent device failures. An external temperature sensor \u003ca href=\"https:\/\/www.crestron.com\/model\/6511514\" title=\"https:\/\/www.crestron.com\/model\/6511514\"\u003ePC-TS\u003c\/a\u003e can be purchased separately to monitor temperature within the equipment rack or room. Network connectivity allows for setup and operation using the web UI, with extensive custom control and monitoring capabilities enabled through integration with Crestron Home® OS, the XiO Cloud® service , and Domotz™ solution.\u003csup\u003e1\u003c\/sup\u003e The PC-350V-18 can also be integrated with a custom-programmed Crestron control system via \u003ca href=\"https:\/\/www.crestron.com\/Products\/Control-Hardware-Software\/Software\/Control-System-Software\/SW-SIMPL\"\u003eSIMPL\u003c\/a\u003e programming software.\u003c\/p\u003e\n\u003cstrong\u003ePower Conditioning\u003c\/strong\u003e\u003cbr\u003e\nThe PC-350V-18 includes the following power conditioning features:\n\u003cul style=\"padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection\u003c\/strong\u003e — Disconnects power to all outlets if surge protection is compromised\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e — Disconnects power to all outlets or the last outlet that drew current exceeding the set threshold values\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnder\/Over Voltage Cutoff\u003c\/strong\u003e — Disconnects power to outlets if the line voltage exceeds the set threshold values\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Breaker\u003c\/strong\u003e — Disconnects power to all outlets in case of an overload condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI\/RFI Noise Filtering\u003c\/strong\u003e — Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Fault Detection\u003c\/strong\u003e — Detects faulty wiring of the incoming AC power line and shuts off power to outlets until the fault is corrected\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Turn On Delay\u003c\/strong\u003e\u003cbr\u003e\nThe PC-350V-18 can be set to the following turn on delays:\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eStartup Delay\u003c\/strong\u003e — The delay sequence between outlets turning on can be set for 1 to 10 seconds . Startup delay ensures that the connected devices power up in a proper sequence and do not overload the circuit or generator.\u003cbr\u003e\n\u003cbr\u003e\nStartup delay is initiated by disconnecting the power controller from the power source and then reconnecting it. It can also be initiated remotely using the web UI, Crestron Home , XiO Cloud , or Domotz.\u003csup\u003e1\u003c\/sup\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eCycle Delay\u003c\/strong\u003e — Up to 300 seconds of delay can be set between the turn off and turn on of an individual outlet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote-Controllable Switched Outlets\u003c\/strong\u003e\u003cbr\u003e\nAny of the PC-350V-18 outlets can be turned on or off individually over the network using the web UI , a Crestron control system, or Domotz. This feature helps to resolve technical issues or power down the select components to save energy when not needed. Through integration with a control system, custom functionality can be programmed to enable control from a touch screen, keypad, remote, or mobile device. Sequential power-up and power-down functionality can be enabled through programming of the control system, with select outlets designated as always on.\u003cbr\u003e\n\u003cbr\u003e\nThe PC-350V-18 integrates seamlessly with Creston Home, enabling the end user to reset connected faulty devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Monitoring\u003c\/strong\u003e\u003cbr\u003e\nBy sensing the incoming line voltage and individual device loads, the PC-350V-18 facilitates a host of solutions for monitoring, automating, and troubleshooting a system.\u003c\/p\u003e\n\u003cul class=\"bullets\" style=\"padding-left: 20px;\"\u003e\n\u003cli\u003eVoltage monitoring tracks and logs fluctuations in the power line, helping to identify and document problems with the power utility or building wiring.\u003c\/li\u003e\n\u003cli\u003eEnergy monitoring per outlet tracks and logs the real power consumption (watts), current draw (amps), and energy usage (watt-hours) for each connected device.\u003c\/li\u003e\n\u003cli\u003eIndividual device usage can be tracked to inform the scheduling of maintenance and future purchasing decisions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Temperature Sensing\u003c\/strong\u003e\u003cbr\u003e\nThe temperature sensor \u003ca href=\"https:\/\/www.crestron.com\/model\/6511514\" title=\"https:\/\/www.crestron.com\/model\/6511514\"\u003ePC-TS\u003c\/a\u003e (available separately) connects to the PC-350V-18 and provides a complete equipment protection solution by monitoring the ambient temperature within the equipment cabinet or room. The PC-350V-18 sends alert notifications when \u003ca href=\"https:\/\/www.crestron.com\/model\/6511514\" title=\"https:\/\/www.crestron.com\/model\/6511514\"\u003ePC-TS\u003c\/a\u003e detects abnormal temperature conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePing Monitoring\u003c\/strong\u003e\u003cbr\u003e\nThe PC-350V-18 can be configured to detect an unresponsive device by sending it a ping command at regular intervals. If the ping request is not returned after a preset number of continuous pings, the outlet feeding the monitored device cycles off and on to reboot the device, quickly restoring normal operation without any human intervention.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScheduling\u003c\/strong\u003e\u003cbr\u003e\nRecurring schedules can be set up to power cycle unused devices to ensure they are operational when needed. The executed schedules are recorded in the logs of the web UI and XiO Cloud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Logging\u003c\/strong\u003e\u003cbr\u003e\nEvents such as overcurrent conditions, over\/under voltage conditions, over-temperature conditions, ping failures, and outlet switching activity can all be logged as they occur to document the time and cause of problems and to track device usage. All sensor readings are logged to record a detailed history of events and energy usage over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Management \u0026amp; Control\u003c\/strong\u003e\u003cbr\u003e\nThe PC-350V-18 integrates seamlessly into any system or facility. It can be set up and managed using the web UI.  Built-in SNMP support enables integration with third-party IT management software, allowing network administrators to manage one or many networked PC-350V-18 devices in an IT-friendly format. The PC-350V-18 can be integrated with a Crestron control system via Ethernet to enable control and monitoring through a touch screen, handheld remote, or mobile device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUL® 1449 Certified\u003c\/strong\u003e\u003cbr\u003e\nSurge protection for PC-350V-18 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).\u003c\/p\u003e\n\n                            \n                                    \u003c\/div\u003e\n\n\n                                     \n                                \u003c\/div\u003e\n\u003cdiv class=\"small-14 medium-4 column medium-offset-1 column end\"\u003e\n\u003cdiv class=\"in-the-box\"\u003e\n\u003ccenter\u003e\u003ca class=\"btn-crestron BTN-RD-FILL-CRESBLUE\" href=\"https:\/\/docs.crestron.com\/en-us\/8214\/Content\/Topics\/Works-With\/Works-with-XiO.htm\" target=\"_blank\"\u003eXiO Cloud\u003cbr\u003e\nSupported Products \u003c\/a\u003e\u003c\/center\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg alt=\"CrestronHome\" class=\"badge\" src=\"https:\/\/kenticoprod.azureedge.net\/kenticoblob\/crestron\/media\/crestron\/generalsiteimages\/badges\/badge_crestronhome-os.jpg?ext=.jpg\"\u003e\n\u003cimg alt=\"XiO Cloud\" class=\"badge\" src=\"https:\/\/kenticoprod.azureedge.net\/kenticoblob\/crestron\/media\/crestron\/generalsiteimages\/badges\/badge-xiocloud2.jpg?ext=.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv class=\"overview_features\"\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically on the rack frame and occupies no rack space (zero RU)\u003c\/li\u003e\n\u003cli\u003e18 Individually-switched outlets with remote control\u003c\/li\u003e\n\u003cli\u003eAdjustable power on sequencing and cycle delay per outlet\u003c\/li\u003e\n\u003cli\u003eBuilt-in current sensing and energy monitoring per outlet\u003c\/li\u003e\n\u003cli\u003eLine voltage, energy, and current monitoring\u003c\/li\u003e\n\u003cli\u003eScheduling for turn on, turn off, and power cycling at set intervals\u003c\/li\u003e\n\u003cli\u003eUL® 1449 Type 3 surge protection\u003c\/li\u003e\n\u003cli\u003eThermal breaker overload protection\u003c\/li\u003e\n\u003cli\u003eAdjustable overvoltage and undervoltage cutoff\u003c\/li\u003e\n\u003cli\u003eEMI and RFI noise filtering\u003c\/li\u003e\n\u003cli\u003eWiring fault detection\u003c\/li\u003e\n\u003cli\u003eAmbient temperature sensing with alert notifications\u003c\/li\u003e\n\u003cli\u003ePing monitoring (device lockup detection and reboot)\u003c\/li\u003e\n\u003cli\u003eBuilt-in energy usage and event logging\u003c\/li\u003e\n\u003cli\u003eEasy setup and operation using the web UI\u003c\/li\u003e\n\u003cli\u003eCrestron® control system integration via Ethernet\u003c\/li\u003e\n\u003cli\u003eRemote management via XiO Cloud® service, Crestron Home® OS, and Domotz™ solution\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntegration with a custom-programmed Crestron control system via SIMPL programming software\u003c\/li\u003e\n\u003cli\u003eRated 12A at 120VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003ePower Conditioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"30%\"\u003eMaximum Output Current, Total\u003c\/td\u003e\n\u003ctd\u003e12A @ 120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current, Per Outlet\u003c\/td\u003e\n\u003ctd\u003e12A @ 120VAC (subject to a maximum total output current of 12A for all outlets combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltration (Outlet 7-18)\u003c\/td\u003e\n\u003ctd\u003e-1.9 dB @ 100 kHz, -25 dB @ 300 kHz, -39 dB @ 500 kHz with 50 Ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection Modes\u003c\/td\u003e\n\u003ctd\u003eLine-Ground, Line-Neutral, Neutral-Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection Shutoff\u003c\/td\u003e\n\u003ctd\u003eShuts off outlets if surge protection is compromised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJoule Rating\u003c\/td\u003e\n\u003ctd\u003e3640 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamping Voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamping Time\u003c\/td\u003e\n\u003ctd\u003e1 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Fault Detection\u003c\/td\u003e\n\u003ctd\u003eShuts off outlets if the following wiring faults are detected at the input:\n\t\t\t\u003cul class=\"bullets\" style=\"padding-left: 20px; padding-top: 5px;\"\u003e\n\u003cli\u003eReversed polarity\u003c\/li\u003e\n\u003cli\u003eMissing ground wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Sensing Range\u003c\/td\u003e\n\u003ctd\u003e90 to 145V rms ±1%, measured at input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Sensing Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 12A rms ±1% when load \u0026gt; 1A, measured per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder Voltage Cutoff\u003c\/td\u003e\n\u003ctd\u003eAdjustable 90 to 100V, shuts off outlets if input drops below set value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Cutoff\u003c\/td\u003e\n\u003ctd\u003eAdjustable 130 to 145V, shuts off rear outlets if input exceeds set value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Delay Adjustment\u003c\/td\u003e\n\u003ctd\u003e5 to 300 seconds, adjustable per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Delay Adjustment\u003c\/td\u003e\n\u003ctd\u003e1 to 10 seconds, adjustable per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Power\u003c\/td\u003e\n\u003ctd\u003e12A @ 120VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eCommunications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps, auto-switching, auto-negotiating, auto-discovery, full\/half duplex, TCP\/IP, UDP\/IP, CIP, DHCP, SSL, TLS, SNMP, web server, web UI setup and control, Crestron control system integration, XiO Cloud monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eConnectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120V~ 12A 60Hz\u003c\/td\u003e\n\u003ctd\u003eDetachable 9.8 ft (3 m) grounded AC power cord with NEMA 5-15P plug, line power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUTLET 1 -18\u003c\/td\u003e\n\u003ctd\u003e(18) NEMA 5-15R AC power outlets;\u003cbr\u003e\n\t\t\tIndividually-switched 120VAC power outlets;\u003cbr\u003e\n\t\t\tAdjustable power cycle delay per outlet;\u003cbr\u003e\n\t\t\tAdjustable startup delay per outlet;\u003cbr\u003e\n\t\t\tRemote switchable per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEMP\u003c\/td\u003e\n\u003ctd\u003e(1) 2-pin 3.5 mm detachable terminal block;\u003cbr\u003e\n\t\t\tConnection for external temperature sensor (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLAN\u003c\/td\u003e\n\u003ctd\u003e(1) 8-pin RJ45 jack;\u003cbr\u003e\n\t\t\t10Base-T\/100Base-TX Ethernet port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eControls \u0026amp; Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR\u003c\/td\u003e\n\u003ctd\u003e(1) Bi-color green\/amber LED, indicates line power is present and:\n\t\t\t\u003cul class=\"bullets\" style=\"padding-left: 20px; padding-top: 5px;\"\u003e\n\u003cli\u003eilluminates amber while booting\u003c\/li\u003e\n\u003cli\u003eilluminates green when the device is operating normally\u003c\/li\u003e\n\u003cli\u003eturns amber if the outlets have been shut off due to a fault condition\u003c\/li\u003e\n\u003cli\u003eblinks in amber during the factory reset process\u003c\/li\u003e\n\u003cli\u003eblinks in green when the \"Identify\" search process is initiated for the unit in the Crestron Home app\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFAULT\u003c\/td\u003e\n\u003ctd\u003e(1) Red LED, indicates any of the following fault conditions:\u003csup\u003e2\u003c\/sup\u003e\n\u003cul class=\"bullets\" style=\"padding-left: 20px; padding-top: 5px;\"\u003e\n\u003cli\u003esurge protection is compromised\u003c\/li\u003e\n\u003cli\u003eline and neutral are reversed\u003c\/li\u003e\n\u003cli\u003eno ground is detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTECT\u003c\/td\u003e\n\u003ctd\u003e(1) Green LED, indicates surge protection is fully functional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHUTDOWN\u003c\/td\u003e\n\u003ctd\u003e(1) Amber LED, indicates power to outlets is shut off due to any of the of the following fault conditions:\n\t\t\t\u003cul class=\"bullets\" style=\"padding-left: 20px; padding-top: 5px;\"\u003e\n\u003cli\u003eovervoltage\u003c\/li\u003e\n\u003cli\u003eundervoltage\u003c\/li\u003e\n\u003cli\u003eovercurrent\u003c\/li\u003e\n\u003cli\u003eline input miswire\u003c\/li\u003e\n\u003cli\u003emissing ground\u003c\/li\u003e\n\u003cli\u003ecompromised surge protection fault condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHW-R\u003c\/td\u003e\n\u003ctd\u003e(1) Recessed pushbutton; Initiates hardware reset, factory restore, DHCP reset, and power cycle of all outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHERMAL BREAKER\u003c\/td\u003e\n\u003ctd\u003e(1) Disconnects power to all outlets in case of an overload condition, press to reset after overload condition is resolved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLAN\u003c\/td\u003e\n\u003ctd\u003e(2) LEDs, green LED indicates Ethernet link status, amber LED indicates Ethernet activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePer Outlet Indicator\u003c\/td\u003e\n\u003ctd\u003e(1) Green LED:\n\t\t\t\u003cul class=\"bullets\" style=\"padding-left: 20px; padding-top: 5px;\"\u003e\n\u003cli\u003eIlluminates when outlet is turned on\u003c\/li\u003e\n\u003cli\u003eblinks when the \"Identify\" search process is initiated for the outlet in the Crestron Home app\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e32° to 104°F (0° to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eConstruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis\u003c\/td\u003e\n\u003ctd\u003eMetal, black finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e0 RU vertically rack-mounted (mounting brackets included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e48.10 in. (1221 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.73 in. (44 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.60 in. (66 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e11.8 lb (5.35 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"productSpecTDHead\" colspan=\"2\"\u003eCompliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cstrong\u003eRegulatory Model: \u003cspan class=\"mc-variable TP-Variables.RegulatoryModel variable\"\u003eM202015001\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\t\t\tUL 62368 Listed, UL 1449 SPD Type 3 , FCC Part 15 class B, IC Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Crestron","offers":[{"title":"Default Title","offer_id":67572555022626,"sku":"PC-350V-18","price":437.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/2228\/6114\/files\/master_photo_a-PC-350V-18_Front.png?v=1792623877","url":"https:\/\/deputyelectronics.com\/products\/crestron-pc-350v-18","provider":"Deputy Electronics","version":"1.0","type":"link"}